| HP ProCurve Switch 3400cl-24G (J4905A) | HP ProCurve Switch 3400cl-48G (J4906A) |
|---|
| Ports |
| 1 open module slot
20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console port
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
Supports a maximum of 24 auto-sensing 10/100/1000 ports plus 2 10-GbE ports
| 1 open module slot
44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console port
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
Supports a maximum of 48 Gigabit ports plus 2 10-GbE ports
|
| Physical characteristics |
| Dimensions | 14.45(d) x 17.32(w) x 1.73(h) in. (36.7 x 44.0 x 4.4 cm) (1U height) | 16.93(d) x 17.32(w) x 1.73(h) in. (43 x 44 x 4.4 cm) (1U height) |
| Weight | 10.27 lb. (4.66 kg) | 10.84 lb. (4.92 kg) |
| Memory and processor |
| Processor | Motorola PowerPC MPC8245 @ 266 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 2 MB (1 MB per 12 ports) | Motorola PowerPC MPC8245 @ 266 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 4 MB (1 MB per 12 ports) |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| 1000 Mb Latency | < 6 µs | < 6 µs |
| 10 Gbps Latency | < 10 µs | < 10 µs |
| Throughput | up to 64 million pps | up to 99.5 million pps |
| Routing/Switching capacity | 88 Gbps | 136 Gbps |
| Routing table size | 64,000 entries | 64,000 entries |
| Environment |
| Operating temperature | 32ºF to 104ºF (0ºC to 40ºC); when used with any X2 10-GbE | 32ºF to 104ºF (0ºC to 40ºC); when used with any X2 10-GbE |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) |
| Acoustic | Power: 53 dB; DIN 45635T.19 per ISO 7779 @ < 80°F (25°C) | Power: 53 dB; DIN 45635T.19 per ISO 7779 @ < 80°F (25°C) |
| Electrical characteristics |
| Description | The switch automatically adjusts to any voltage between 100-127 and 200-240 V and either 50 or 60 Hz | The switch automatically adjusts to any voltage between 100-127 and 200-240 V and either 50 or 60 Hz |
| Maximum heat dissipation | 307 BTU/hr (324 kJ/hr), including use of optional cl module with optics | 482 BTU/hr (509 kJ/hr), including use of optional cl module with optics |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 2.0 / 1.0 A | 3.0 / 1.5 A |
| Maximum power rating | 90 W | 141 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. Maximum BTUs includes use of optional cl module with optics. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. Maximum BTUs includes use of optional cl module with optics. |
| Safety |
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 60950
| CSA 22.2 No. 60950 EN 60950/IEC 60950 UL 60950
|