| HP ProCurve Switch 2510-24 (J9019B) | HP ProCurve Switch 2510-48 (J9020A) | HP ProCurve Switch 2510G-24 (J9279A) |
|---|
| Ports |
| 24 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
1 RJ-45 serial console port
| 48 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
1 RJ-45 serial console port
| 20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RJ-45 serial console port
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
| Physical characteristics |
| Dimensions | 9.3(d) x 17.42(w) x 1.73(h) in. (23.62 x 44.25 x 4.39 cm) (1U height) | 9.3(d) x 17.42(w) x 1.73(h) in. (23.62 x 44.25 x 4.39 cm) (1U height) | 12.7(d) x 17.4(w) x 1.7(h) in. (32.26 x 44.2 x 4.32 cm) (1U height) |
| Weight | 4.89 lb. (2.22 kg), Fully loaded | 6.05 lb. (2.74 kg), Fully loaded | 7.21 lb. (3.27 kg) |
| Memory and processor |
| Processor | MIPS 32 @ 264 MHz, 8 MB flash, 64 MB SDRAM; packet buffer size: 384 KB | MIPS 32 @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 512 KB | MIPS @ 264 MHz, 16 MB flash, 64 MB SDRAM; packet buffer size: 0.75 MB |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency | | | < 5.6 µs (FIFO 64-byte packets) |
| 100 Mb Latency | < 4.9 µs (64-byte packets) | < 4.9 µs (64-byte packets) | |
| 1000 Mb Latency | < 2.6 µs (64-byte packets) | < 2.9 µs (64-byte packets) | |
| Throughput | up to 6.5 million pps (64-byte packets) | up to 13 million pps (64-byte packets) | up to 35.7 million pps |
| Switching capacity | 8.8 Gbps | 17.6 Gbps | 48 Gbps |
| MAC address table size | 8,000 entries | 8,000 entries | 8,000 entries |
| Environment |
| Operating temperature | 32ºF to 113ºF (0ºC to 45ºC) | 32ºF to 113ºF (0ºC to 45ºC) | 32ºF to 113ºF (0ºC to 45ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 90% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 10,000 ft. (3 km) | up to 15,000 ft. (4.6 km) | up to 10,000 ft. (3 km) |
| Acoustic | Power: 0 dB no fan | Power: 43.6 dB; DIN 45635T.19 per ISO 7779 | Power: 40.3 dB |
| Electrical characteristics |
| Maximum heat dissipation | 68 BTU/hr (71.74 kJ/hr) | 92 BTU/hr (97 kJ/hr) | 164 BTU/hr (173 kJ/hr) |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 0.7 / 0.4 A | 1.2 / 0.7 A | 1.0 A |
| Maximum power rating | 20 W | 27 W | |
| Power output | | | 48 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | |
| Safety |
| cUL (CSA 22.2 No. 60950) UL 60950-1 IEC 60950 EN 60950
| cUL (CSA 22.2 No. 60950) UL 60950-1 IEC 60950 EN 60950
| cUL (CSA 22.2 No. 60950) UL 60950-1 IEC 60950 EN 60950
|
| Notes |
| | | When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
|