| HP ProCurve Switch 5308xl (J4819A) | HP ProCurve Switch 5372xl (J4848B) | HP ProCurve Switch 5348xl (J4849B) |
|---|
| Included accessories |
| | 3 HP ProCurve Switch xl 24-Port 10/100-TX Module (J4820B)
| 2 HP ProCurve Switch xl 24-Port 10/100-TX Module (J4820B)
|
| Ports |
| 8 open module slots
Supports a maximum of 192 auto-sensing 10/100 ports or 128 auto-sensing 10/100/1000 ports
| 5 open module slots
72 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
Supports a maximum of 192 auto-sensing 10/100 ports or 128 auto-sensing 10/100/1000 ports
| 2 open module slots
48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
Supports a maximum of 96 auto-sensing 10/100 ports or 64 auto-sensing 10/100/1000 ports
|
| Power supplies |
| 1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
| 1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
| 1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
|
| Physical characteristics |
| Dimensions | 15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height) | 15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height) | 15.3(d) x 17.4(w) x 5.25(h) in. (38.86 x 44.2 x 13.34 cm) (3U height) |
| Weight | 26.65 lb. (12.0 kg), Fully loaded | 31.05 lb. (14.08 kg), Fully loaded | 24.65 lb. (11.2 kg), Fully loaded |
| Memory and processor |
| Fabric | Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM; packet buffer size: 36 MB | Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM | Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM |
| Module | | ARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer size: 36 MB | ARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer size: 36 MB |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency | < 6 µs (FIFO) | < 6 µs (FIFO) | < 6 µs (FIFO) |
| Throughput | up to 48 million pps | up to 48 million pps | up to 24 million pps |
| Switch fabric speed | 76.8 Gbps | 76.8 Gbps | 38.4 Gbps |
| Routing table size | 10,000 entries | 10,000 entries | 10,000 entries |
| Environment |
| Operating temperature | 32ºF to 104ºF (0ºC to 40ºC) | 32ºF to 104ºF (0ºC to 40ºC) | 32ºF to 104ºF (0ºC to 40ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) |
| Electrical characteristics |
| Maximum heat dissipation | 2152 BTU/hr (2270 kJ/hr) | 2152 BTU/hr (2270 kJ/hr) | 2152 BTU/hr (2270 kJ/hr) |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 8.2 / 3.8 A | 8.2 / 3.8 A | 8.2 / 3.8 A |
| Maximum power rating | 630 W | 630 W | 630 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition
| cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition
| cUL (CSA 950) EN 60950/IEC 60950 NOM-019-SCFI-1994 UL 1950 3rd edition
|