| HP ProCurve Switch 4208vl-96 (J8775B) | HP ProCurve Switch 4204vl-48GS (J9064A) | HP ProCurve Switch 4208vl-72GS (J9030A) |
|---|
| Included accessories |
| 4 HP ProCurve Switch vl 24-Port 10/100-TX Module (J8765A)
| 1 HP ProCurve Switch vl 24-Port Gig-T Module (J8768A)
1 HP ProCurve Switch vl 20-Port Gig-T + 4-Port SFP Module (J9033A)
| 2 HP ProCurve Switch vl 24-Port Gig-T Module (J8768A)
1 HP ProCurve Switch vl 20-Port Gig-T + 4-Port SFP Module (J9033A)
|
| Ports |
| 4 open module slots
96 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
Supports a maximum of 192 auto-sensing 10/100 ports or 96 auto-sensing 10/100/1000 ports or 16 mini-GBICs or 4 10-GbE ports, or a combination
| 2 open module slots
44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 open mini-GBIC (SFP) slots
Supports a maximum of 48 auto-sensing 10/100 ports or 92 auto-sensing 10/100/1000 ports or 12 mini-GBICs or 2 10-GbE ports, or a combination
| 5 open module slots
68 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 open mini-GBIC (SFP) slots
Supports a maximum of 120 auto-sensing 10/100 ports or 188 auto-sensing 10/100/1000 ports or 24 mini-GBICs or 4 10-GbE ports, or a combination
|
| Power supplies |
| 1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
| 1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
| 1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
|
| Physical characteristics |
| Dimensions | 15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height) | 15.3(d) x 17.4(w) x 5.25(h) in. (38.86 x 44.2 x 13.34 cm) (3U height) | 15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height) |
| Weight | 32.3 lb. (14.65 kg), Fully loaded | 24.45 lb. (11.09 kg), Fully loaded | 30.88 lb. (14.01 kg), Fully loaded |
| Memory and processor |
| Fabric | Motorola PowerPC MPC8245 @ 330 MHz, 24 MB flash, 64 MB SDRAM; packet buffer size: 36 MB | Motorola PowerPC MPC8245 @ 330 MHz, 24 MB flash, 64 MB SDRAM; packet buffer size: 36 MB | Motorola PowerPC MPC8245 @ 330 MHz, 24 MB flash, 64 MB SDRAM; packet buffer size: 36 MB |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency | < 6 µs (FIFO) | < 6 µs (FIFO) | < 6 µs (FIFO) |
| Throughput | up to 48 million pps | up to 24 million pps | up to 48 million pps |
| Switch fabric speed | 76.8 Gbps | 38.4 Gbps | 76.8 Gbps |
| Environment |
| Operating temperature | 32ºF to 104ºF (0ºC to 40ºC) | 32ºF to 104ºF (0ºC to 40ºC) | 32ºF to 104ºF (0ºC to 40ºC) |
| Operating relative humidity | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing | 15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) | -40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing | 15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) | up to 15,000 ft. (4.6 km) |
| Acoustic | Power: 64.2 dB; DIN 45635T.19 per ISO 7779 | Power: 64.2 dB; DIN 45635T.19 per ISO 7779 | Power: 64.2 dB; DIN 45635T.19 per ISO 7779 |
| Electrical characteristics |
| Maximum heat dissipation | 2152 BTU/hr (2270 kJ/hr) | 2152 BTU/hr (2270 kJ/hr) | 2152 BTU/hr (2270 kJ/hr) |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 8.2 / 3.8 A | 8.2 / 3.8 A | 8.2 / 3.8 A |
| Maximum power rating | 630 W | 630 W | 630 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| CSA 22.2 No. 950 UL 60950 EN 60950
| CSA 22.2 No. 950 UL 60950 EN 60950
| CSA 22.2 No. 950 UL 60950 EN 60950
|
| Notes |
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
| When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
|