| HP ProCurve Secure Router 7102dl (J8752A) | HP ProCurve Secure Router 7203dl (J8753A) |
|---|
| Ports |
| 2 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 open dl module slots
1 RS-232C DB-9 console port
1 Compact Flash port
1 VPN encryption module slot
500 max VPN sessions
| 2 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 open dl module slots
1 open dl wide module slot
1 RS-232C DB-9 console port
1 Compact Flash port
1 VPN encryption module slot
1000 max VPN sessions
|
| Physical characteristics |
| Dimensions | 11.52(d) x 17.42(w) x 1.73(h) in. (29.26 x 44.25 x 4.39 cm) (1U height) | 11.52(d) x 17.42(w) x 1.73(h) in. (29.26 x 44.25 x 4.39 cm) (1U height) |
| Weight | 10.26 lb. (4.62 kg) | 10.95 lb. (4.93 kg) |
| Memory and processor |
| 32 MB flash, 128 MB SDRAM | 32 MB flash, 256 MB SDRAM |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| WAN throughput | 150 kpps up to 4xT1/E1 lines | 210 kpps up to 8xT1/E1 lines |
| Environment |
| Operating temperature | 32ºF to 122ºF (0ºC to 50ºC) | 32ºF to 122ºF (0ºC to 50ºC) |
| Operating relative humidity | 0% to 95%, non-condensing | 0% to 95%, non-condensing |
| Non-operating/Storage temperature | -4ºF to 158ºF (-20ºC to 70ºC) | -4ºF to 158ºF (-20ºC to 70ºC) |
| Non-operating/Storage relative humidity | 0% to 95%, non-condensing | 0% to 95%, non-condensing |
| Electrical characteristics |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 0.4 / 0.2 A | 0.4 / 0.2 A |
| Maximum power rating | 15 W | 50 W |
| Frequency | 50 / 60 Hz | 50 / 60 Hz |
| Notes | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. | Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated. |
| Safety |
| CSA 22.2 No. 60950 3rd edition CE Labeled cUL Certified EN 60950/IEC 60950, 3rd edition UL Listed AS/NZS 60950 KN 60950 GOST R MEK60950 TS 60950 UL 60950
| CSA 22.2 No. 60950 3rd edition CE Labeled cUL Certified EN 60950/IEC 60950, 3rd edition UL Listed AS/NZS 60950 KN 60950 GOST R MEK60950 TS 60950 UL 60950
|